Specs and Requirements
Front Panel
* 8 Button Tactile Raised keypad:
Mode, Select, Enter, Escape, Up, Down,Left, Right
* Blue Translucent LCD
20 character by 2 row
* Front Panel Host LED’s
Power, Alarm, Link, Busy, MPE
* Front Panel LEDs
In : 1 - 10 ASI
Out : Alarm, ASI, SMPTE 310, CA, GigE
ASI Inputs
* ASI x 10 (BNC)
* 188 or 204 Byte mode
* SPTS or MPTS
* 211 Mbps per input
* 256 PIDs per input
* Fill scrubbing on input
* Input Modes
Auto (Remap all services)
Manual (Add/Drop/Remap PID/Services)
Pass (Pass all services as-is)
MHP Injector
SI Injector
Redundancy
* 1+1 IP and ASI
* ASI x 2 (BNC inputs for auto switch)
* No external controller required
Outputs
* Gigabit Ethernet
SPTS over UDP or RTP
MPTS over UDP or RTP
211 Mbs
Very low jitter
* ASI
(model is DTA 3050-ASI)
Mirrored (BNC x 3)
Byte or Burst Mode
54 Mbs Byte
211 Mbs Burst
Jitter less than 150 (nS)
* SMPTE-310
(model is DTA 3050-SMPTE-310)
Mirrored (BNC x 2)
Byte Mode only
19.39 Mbs fixed
SMPTE-310 option includes ASI
Table Processing
* No Tables
* MPEG Tables
PAT
CAT (if CA is enabled)
PMT
* DVB Tables (Add/Drop/Remap DVB Services)
NIT
SDT
TDT/TOT
EIT
* ATSC Tables (Add/Drop/Remap ATSC Services)
VCT (Cable or Terrestrial)
MGT
STT
RRT
EIT (1-4)
* DCII Tables (Add/Drop/Remap Digicypher services to DVB or ATSC)
IP Data Encapsulation (ISO 13818-6 MPE)
* EN 301 192 Encapsulation of IP Datagrams over
* Unicast and Multicast Support
* 32 Routes
* 32 PIDs
IP Data de-capsulation (ISO 13818-6 MPE)
* EN 301 192 de-capsulation of IP Datagrams
Conditional Access Encryption
* DVB-Common Scrambling Algorithm (CSA)
* DVB Simulcrypt TS 103 197 v 1.2.1 and SCTE
OpenCAS™ DVS-278 compliant
* FIPS 140-2 hardware based random number generator (RNG)
* Advanced Encryption Standard (AES)
Adtec Open Secure Transport (OST)
IP based encryption for use with Adtec IRDs
IP Set Top and Computer compatibility
* Approved 3rd Party CA Vendors include:
CSA:
Irdeto
Conax
EuroCAS
KeyFly
Xcrypt
* AES:
Verimatrix
Adtec OST
Host Platform
* PowerPC
* Adtec optimized Linux Kernel
* 10/100 Ethernet RJ-45 (Eth 0)
* 10/100/1000 Ethernet RJ-45 (Eth 1)
* Serial Port (RJ-48)
* USB 2.0 (2)
* IEEE 1394 (Firewire)
* N.C. / N.O. Tally Interface
* XML Configuration
* HTTP, FTP, Telnet, IP Logging, DHCP,
(XCP Adtec encrypted layer 3 protocol)
Power
* 70-240 VAC switching power supply
* 50/60 Hertz
* Rated at 94 Watts return nominal usage 20 watts
Physical
* 19” wide, 1.75” tall, 16” deep, (483 x 44.5 x 406 mm)
* 1 Rack Unit
* Weight 13lbs.
Environmental
* Active cooling (Push pull Fans)
* Operating: 0 to +50 degrees C
* Storage: -30 to +65 degrees C
* Less than 70% RH
* Non-Condensing
|
|
|